AIR QUALITY ONLINE MONITORING SYSTEM
Model:
ES80A-A6
I . Purpose Designed For Outdoors;Real-Time NO2, CO, O3, SO2,PM2.5,PM10,TSP,Meteorological Parameter ;Access Air Quality Data 24H / 365 Days; Remote WLAN And 4G Connectivity;II. Optional:Wind Speed/Direction And Noise Sensors;Battery/Solar Power OptionalIII. Air Quality Online Monitoring System Is An Instrument Based On The Principle Of Light Scattering, Providing NO2, CO, O3, SO2,PM2.5,PM10,TSP,Wind Speed & Direction, Temperature& Humidity, Noise Detection And Other Defensive And Accurate Quality Measurements;IV. Application Scenario:1.Street Intersections,Highways Etc2.Petrochemicals, Mining,Steel Mills, Oil Refineries3.Residential Complexes,Schools,Hospitals;4.Forest Fire Alarm, Agricultural Straw Burning;5.Garbage Disposal, Tourist Attractions; Product Name/ModelAir Quality Online Monitoring System/ES80A-A6 Diffusion /Detection MethodSuctionData TransmissionRS485 Modbus, 4G LTEPreheat Time90 SecondsTemperature-20℃~50℃Humidity10%RH ~95%RH (No Condensation)Power SupplyAC110Vor AC220V/50Hz, Optional Solar Power SupplyPower Consumption80W(MAX)Host Size620*440*160MMThe Main MaterialCold Rolled Steel PlateInstallation MethodOutdoor Column InstallationProtection ClassIP65 Gas Selection The Standard ConfigurationGas FactorMeasuring RangeResolutionIndication ErrorT90O31000ppb1ppb≤±5%FS120SNO21000ppb1ppb≤±5%FS120SSO21000ppb1ppb≤±5%FS120SCO200ppm0.1ppm≤±5%FS120S Gas Selection Optional GasesGas FactorMeasuring RangeResolutionIndication ErrorT90TVOC10ppm0.1ppm≤±10%FS120SH2S20ppm0.1ppm≤±10%FS120SNH320ppm0.1ppm≤±10%FS120S*Note: The Indication Error Is Measured In The Laboratory Environment.Need Other Gases, Please Contact Us. Particulate Technical ParametersProjectTechnical IndicatorsMeasuring RangePM2.5(0-2000)ìg/m3 , PM10 (0-2000) ìg/m3Sampling CutterCyclone Physical CutterSampling TimeAdjustable, Default Five MinutesResolution1ug/m3Particle SizePM2.5, PM10, TSPSampling ModeSuction TypeAir Intake HeatingHeating And Dehumidifying According To Air HumidityMalfunction AlarmReal-Time DisplayZero MethodAutomatic zero calibration Specification Parameter Information Meteorological And Other Parameters(Optional)Monitoring ParametersRangeResolutionAccuracyTemperature-30℃--50℃0.1℃±1℃Humidity0-95%Rh1%Rh±5%RhWind Speed0~60m/s0.1 m/s±1m/sWind Direction0-360°1°/WindLevel 0-15Level 1/Atmospheric Pressure600—1100hPa1 hPa/Noise30dB(A)~130dB(A)(A-weighted)/±3dBRainfall0~4mm/min0.1mm±0.4mm (≤10mm)±4% (>10mm)Illumination0~200,000 Lux/±7% (25℃)UV Radiation0~400mW/1mW/±5%
Keywords:
AIR QUALITY ONLINE MONITORING SYSTEM
Category:
Download:
Whatsapp:
Product Description
I . Purpose Designed For Outdoors;
Real-Time NO2, CO, O3, SO2,PM2.5,PM10,TSP,Meteorological Parameter ;
Access Air Quality Data 24H / 365 Days; Remote WLAN And 4G Connectivity;
II. Optional:Wind Speed/Direction And Noise Sensors;Battery/Solar Power Optional
Main technical parameters
| Product Name/Model | Air Quality Online Monitoring System/ES80A-A6 Diffusion / | |||
| Detection Method | Suction | |||
| Data Transmission | RS485 Modbus, 4G LTE | |||
| Preheat Time | 90 Seconds | |||
| Temperature | -20℃~50℃ | |||
| Humidity | 10%RH ~95%RH (No Condensation) | |||
| Power Supply | AC110Vor AC220V/50Hz, Optional Solar Power Supply | |||
| Power Consumption | 80W(MAX) | |||
| Host Size | 620*440*160MM | |||
| The Main Material | Cold Rolled Steel Plate | |||
| Installation Method | Outdoor Column Installation | |||
| Protection Class | IP65 | |||
| Gas Selection The Standard Configuration | ||||
| Gas Factor | Measuring Range | Resolution | Indication Error | T90 |
| O3 | 1000ppb | 1ppb | ≤±5%FS | 120S |
| NO2 | 1000ppb | 1ppb | ≤±5%FS | 120S |
| SO2 | 1000ppb | 1ppb | ≤±5%FS | 120S |
| CO | 200ppm | 0.1ppm | ≤±5%FS | 120S |
| Gas Selection Optional Gases | ||||
| Gas Factor | Measuring Range | Resolution | Indication Error | T90 |
| TVOC | 10ppm | 0.1ppm | ≤±10%FS | 120S |
| H2S | 20ppm | 0.1ppm | ≤±10%FS | 120S |
| NH3 | 20ppm | 0.1ppm | ≤±10%FS | 120S |
| *Note: The Indication Error Is Measured In The Laboratory Environment. Need Other Gases, Please Contact Us. | ||||
| Particulate Technical Parameters | ||||
| Project | Technical Indicators | |||
| Measuring Range | PM2.5(0-2000)ìg/m3 , PM10 (0-2000) ìg/m3 | |||
| Sampling Cutter | Cyclone Physical Cutter | |||
| Sampling Time | Adjustable, Default Five Minutes | |||
| Resolution | 1ug/m3 | |||
| Particle Size | PM2.5, PM10, TSP | |||
| Sampling Mode | Suction Type | |||
| Air Intake Heating | Heating And Dehumidifying According To Air Humidity | |||
| Malfunction Alarm | Real-Time Display | |||
| Zero Method | Automatic zero calibration | |||
| Specification Parameter Information | ||||
| Meteorological And Other Parameters(Optional) | ||||
| Monitoring Parameters | Range | Resolution | Accuracy | |
| Temperature | -30℃--50℃ | 0.1℃ | ±1℃ | |
| Humidity | 0-95%Rh | 1%Rh | ±5%Rh | |
| Wind Speed | 0~60m/s | 0.1 m/s | ±1m/s | |
| Wind Direction | 0-360° | 1° | / | |
| Wind | Level 0-15 | Level 1 | / | |
| Atmospheric Pressure | 600—1100hPa | 1 hPa | / | |
| Noise | 30dB(A)~130dB(A) (A-weighted) | / | ±3dB | |
| Rainfall | 0~4mm/min | 0.1mm | ±0.4mm (≤10mm) ±4% (>10mm) | |
| Illumination | 0~200,000 Lux | / | ±7% (25℃) | |
| UV Radiation | 0~400mW/ | 1mW/ | ±5% | |