Features Ambient temperature :10℃~32℃.Accurate Temperature control technology to make the temperature maintain -40 ℃~-86 ℃ and accuracy 0.1 ℃.Independent research and development of mixed refrigerant can make device save energy 50%.if one system breaks down the left one could continue working to maintain inner temp at - 80C, this means you would have double safety guarantee for your storage insideThe first dual system invented and released in domestic market with the rapid cooling speed to cool down from room temperature to -80 in 3.5hours.304 stainless steel inner chamber for friendly using and easy cleaning.VIP II PLUS technology, special narrow design for entering elevators.Safety Build-in back-up battery to display temperature and to operate audible and visual alarm system for up to 72 hours without AC power.Visual and audible alarm system:High/low temperature,Power failure,Abnormal voltage,Sensor error,Filter screen check,Low battery,Condenser clean,High ambient temperature,Door ajar alarmPower failure protection: turn on delay of the cooling system when power failure,restart delay protection.Keyboard lock, password protection to avoid set parameter randomly.Special noise reduction design.Humanized design 4 casters with stopper for easy moving and fixation.Standard 25mm test hole for easy connecting to temperature monitoring systems.3 adjustable shelves for easy storing.Removable condenser dust gauze convenient for cleaning and maintenance.Removable inner door for user to defrost and clean.Standard USB port,USB port to read temperature and alarm conditions in recent 1 months.Special: Patented technology, mixed refrigerant.Standard remote alarm port10 visual and audible alarms.
Model:
FSF-5V150L,FSF-5V395L,FSF-5V455L,FSF-5V635L,FSF-5V795L, FSF-5V1150L
Microcomputer temperature control enables the internal temperature to be adjustable between -10°C to -25°C .(Temperature resolution: 1°C)Equipped with an efficient refrigeration system; Optimized evaporator pipeline design;Wide voltage design;Power-off memory function; Universal casters with locking feet design.Double-layer tempered glass electric heating door prevents condensation in high-humidity environment, keeping samples visible.
Features Adjustable temperature range 2-8℃Microprocessor control, digital display, and temperature adjustment with an increment of 0.1℃ Large digital display screenTemperature variation within ±3℃Permanently lubricated cooling fan for safety and longevityHigh efficiency specialty compressor with known field reliabilityForced- air cooling with optimized air distribution system designedSafetyBuild-in back-up battery to display temperature and to operate audible and visual alarm system for up to 8 hours without AC power.Visual and audible alarm system:High/low temperature, thermostat failure alarm,power failure alarm, door ajar.Power failure protection: turn on delay of the cooling system when power failure,restart delay protection.Keyboard lock, password protection to avoid set parameter randomly.Wide available voltage range: 187V~242V.Humanized design Optimized space utilization design with multi - level and adjustable shelf height to accommodate storage requirement of pharmaceutical products of various kinds.Standard with LED Interior lightSafety lock to prevent unauthorized access
Features Adjustable temperature range 2-8℃ Microprocessor control, digital display, and temperature adjustment with an increment of 0.1℃ Large digital display screenTemperature variation within ±3℃Permanently lubricated cooling fan for safety and longevityHigh efficiency specialty compressor with known field reliabilityForced- air cooling with optimized air distribution system designedSafety Build-in back-up battery to display temperature and to operate audible and visual alarm system for up to 8 hours without AC power.Visual and audible alarm system:High/low temperature, thermostat failure alarm,power failure alarm, door ajar.Power failure protection: turn on delay of the cooling system when power failure,restart delay protection.Keyboard lock, password protection to avoid set parameter randomly.Wide available voltage range: 187V~242V.Humanized Design 4 casters with stopper for easy moving and fixation.10 adjustable shelves for easy storing. Safety lock to prevent unauthorized access .Auto on/off LED light with manual switch on control panel.
Features Accurate Temperature control technology to make the temperature maintain 2~8℃and increment 0.1℃.Specially designed forced-air cooling system to ensure frost-free cabinet and good temperature uniformity.Designed for ambient temperature 10~32℃with humidity below 95%.Three layer toughened glass door with heater to avoid condensation.Color spray steel plate inner chamber for friendly using and easy cleaning.Wide available voltage range: 187V~242VSafety Safety door lock and controller setting password to prevent unauthorized access.Build-in back-up battery to display temperature and to operate audible and visual alarm system for up to 8 hours without AC power.Auto on/off cooling fan to prevent cold air from leaking out when the door is opening.Visual and audible alarm system: High/low temperature, power failure, sensor error, door ajarPower failure protection: turn on delay of the cooling system after power failure.Controller error protection: the cooling system will remember the normal working cycle and keep working depending on this memory when controller or two sensor failed.Humanized design 4 casters,and two with stopper for easy moving and fixation.10 adjustable shelves for easy storing.Special designed service-free drainage system, ensure no water in the cabinet.Auto on/off LED light with manual switch on control panel.Automatic spring back design of double heated glass doorStandard test hole for convenient installation of temperature recorder
Features Adjustable temperature range 2-8℃Microprocessor control, digital display, and temperature adjustment with an increment of 0.1℃ Large digital display screenTemperature variation within ±3℃Permanently lubricated cooling fan for safety and longevityHigh efficiency specialty compressor with known field reliabilityForced- air cooling with optimized air distribution system designedSafety Build-in back-up battery to display temperature and to operate audible and visual alarm system for up to 8 hours without AC power.Visual and audible alarm system:High/low temperature, thermostat failure alarm,power failure alarm, door ajar.Power failure protection: turn on delay of the cooling system when power failure,restart delay protection.Keyboard lock, password protection to avoid set parameter randomly.Wide available voltage range: 187V~242V.Humanized Design Optimized space utilization design with multi - level and adjustable shelf height to accommodate storage requirement of pharmaceutical products of various kinds.Standard with Auto on/off LED Interior light with manual switch on control panel.Safety lock to prevent unauthorized access4 casters with stopper and 2 adjustable feet for easy moving and fixation.
Model:
LW160 LW190 LW190P LW220 LW220H LW230 LW230H LW320 LW320H LW640
Microcomputer chip control technology(non-PLC)The main control circuit adopt gold-plating technology and military-grade electronic devices;Full color OLED LCD touch screen operating system;Fingerprint recognition system and SD card;30 standard program and 120 self-defined program;Variable frequency soft-start functionThe circulating water can be adjusted from 0-1600L/min. The pipeline pressure was monitored through sensor in real-time and the pump can be stopped when the pressure is too low or disappear.Back water supply methodThe pressure is uniform and the water outlet height is same.module can be changed freely,cleaning basket adopt quick-plug design, easy to install.Cleaning basket adopt FL-EXCH module design, every 1/2 module can be changed freely,cleaning basket adopt quick-plug design, easy to install.Black box was set to record the running statusBuzzing and panel reminding after the cleaning, cleaning data can be stored and printed.Safety protection systemWater heating over temperature protection,hot air heating over temperature protection,monitoring water leakage.The instrument will recovery automatically after water cut,and have the remain function when the cleaning agent is lacking.Multi-layer filtration system to prevent pollutants.
Model:
CTLW-60,CTLW-200A,CTLW-120,CTLW-200,CTLW-220,CTLW-320,CTMW-220,CTMW-320,CTMW-420
Features Microprocessorwith PLCcontrol system anti-EMI (electrical magnetic interface). 7"colorfultouchscreen is easy control and observation, and it display the work situation. Passwordprotectionwith three levels can meet different management needs which block the authorized entry. Parameterssetting memory forpower failure, washer cycles is going on as soon as power comes back. Safetyprotection water temperature and dry air temperature, when the temperature exceed the setting, it will stop working.Safetylockwith electromagnetic release to prevent door opening while it is in wash/dry cycle. Safetyelectrical system for circuit overload, short circuit, over current and leakage current. Safetyemergencybuttonfor stop the unit in time. The doorisanti-fall and anti-rebound design, and can be stopped at any angle from 0 to 90 degrees after opening. Alarm system:circulating pump overheated, water heating abnormal, air heating abnormal, cleaning agent shortage, door is not closed, water intake abnormal, overflow alarm, etc. USBportforexportingall the data relative to completed washing and disinfection programs. FilterSystem: Twostainless steel filters protect re-circulation and drain pumps from debris; DualPeristaltic Pumps (Detergent & Neutraliser): with two peristaltic pumps dedicated to dispensing the alkaline detergent during the cleaning phase and the acid neutralizer during the neutralization phase respectively. The patented TWINS drying system ensures 360°dead-angle-free hot air circulation, synchronously drying both utensils and pipelines to prevent bacterial growth caused by residual moisture. The forced-air drying system combines an intelligent PLC-controlled hot air generator and adjustable fan speed for rapid, energy-efficient drying at temperatures up to 120°C, optimizing glassware sanitation and process speed. The microprocessor control system features a 7-inch color LCDtouchscreen with PLC programmability, offering 99 customizable cycles, adjustable parameters (time, temperature, additives, water settings), real-time monitoring, password protection, and power-off memory. The CTLW120-320 series offers 12presetcleaning programs forcommoncontaminants plus 99 customizable PLC programs, allowing users to tailor washing steps, temperature, duration, detergent dosage, and drying settings for each cycle. The system offers1-3 wash levels with automatic rack actuation, universal and interchangeable cleaning racks across models, and flexible height adjustment for versatile utensil cleaning." The monitoring system ensures safety and quality controlthrough audible/visual alarms and dual water level sensors to prevent overflow during wash cycles. The water in jection system features dual inlets (tap/pure water) with electromagnetic valvecontrol, while automatic water/gas connections on each level minimize pressure loss for effective washing and drying. Dual pump system ensures efficient washing and draining, preventing cross-contamination and back flow while enhancing cleaning power.